Mechanical Engineering - Mock Test - 8

Q1:

In milk chilling plants, the usual secondary refrigerant is

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q2:

Air cooling is used for Freon compressors whereas water jacketing is adopted for cooling ammonia compressors. This is because

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q3:

Vapour absorption refrigeration system works using the

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q4:

Hydrogen is essential in an Electrolux refrigeration system beasuse

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q5:

Which one of the following statement regarding ammonia absorption system is correct?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q6:

Consider the following statements:

In ammonia refrigeration system, oil separator is provided because

1. Oil separation in evaporator would lead to reduction in heat transfer coefficient.

2. Oil accumulation in the evaporator causes choking of evaporator.

3. Oil is partially miscible in the refrigerant.

4. Oil cause choking of expansion device.

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q7:

Consider the following statements:

1. Practically all common refrigerants have approximately the same COP and power requirement.

2. Ammonia mixes freely with lubricating oil and this helps lubrication of compressors.

3. Dielectric strength of refrigerant is an important property in hermetically sealed compressor units.

4. Leakage of ammonia can be detected by halide torch method.

Which of these statements are correct?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q8:

Match List-I (Basic components of aqua-ammonia refrigeration system) with List-II (Functions of the components in the system) and select the correct answer using codes given below the lists:

List-I

List-II

A. Generator

1. Dehydration

B. Analyzers

2. Removal of vapour from strong aqua ammonia solution

C. Rectifier

3. Producing dry ammonia vapour by removing traces of water particles completely

D. Receiver

4. Storage of high pressure liquid ammonia

 

5. Formation of liquid ammonia from high pressure vapours.

 

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q9:

Waste heat can be effectively used in which one of the following refrigeration system?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q10:

The sensible heat factor of a room is given by (S.H.L = Sensible heat load and L.H.L. = Latent heat load)

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q11:

A single-acting two-stage compressor with complete inter cooling delivers air at 16 bar. Assuming an intake state of 1 bar at 15°C, the pressure ratio per stage is:

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q12:

In a centrifugal compressor assuming the same overall dimensions, blade inlet angle and rotational speeds, which of the following blading  will given the maximum pressure rise?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q13:

Consider the following characteristics:

1. The fluid enters the pump axially and is discharged radially.

2. Maximum efficiency may be of the order of 90%.

3. Development of a low head

4. A limited suction capacity

Which of the above characteristics are possessed by axial flow pumps?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q14:

In a vapour compression refrigeration system, the high pressure liquid from the condenser / receiver is cooled down below its saturation temperature to

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q15:

An ideal vapour compression refrigerator operates between a condenser pressure P1 and an evaporator pressure P2. Which of the following changes would increase its COP?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q16:

A vapour compression refrigeration has a COP of 4 and extracts 10 KJ of heat from the cold reservoir. If this machine is worked as a heat pump , how much heat will it deliver to the environment ?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q17:

State of wet vapour can not be specified only by

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q18:

In vapour compression refrigeration system, at entrance to which component the working fluid is superheated vapour?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q19:

When a refrigerator system is started  from ambient conditions, the evaporator temperature decreases from ambient temperature to design value. This period is known as a pull-down period. The power require by compressor during pull-down period is

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q20:

Subcooling heat exchanger is used in  a refrigeration cycle. The enthalpies at condenser outlet and evaporator outlet are 78 and 182 kJ/kg respectively. The enthalpy at outlet of isentropic Compressor is 230 kJ/kg and enthalpy of sub cooled liquid is 68 kJ/kg. The COP of the cycle is

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q21:

A standard vapour compression refrigeration cycle consists of the following four thermodynamic processes in sequence

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q22:

Which one of the following is correct?

During sensible cooling of moist air, its relative humidity

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q23:

During sensible cooling of air,

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q24:

Consider the following statements regarding Psychrometric processes:

1. Sensible heating is a process in which moisture content remains unchanged.

2. In the dehumidification process the dew point temperature remains same.

3. The process of adding moisture at constant dry bulb temperature is known as pure humidification process.

Which of the statements given above is/are correct?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q25:

Which one of the following is correct?

On Psychrometric chart, the constant wet bulb temperature lines coincide with.

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q26:

Consider the following statements in a Psychrometric  chart

1 Vertical lines indicate wet bulb temperature

2 Horizontal lines indicate specific humidity

3 Sensible heating or cooling is represented by an inclined line which of the statements given above is/are correct 

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q27:

When the wet bulb and dry bulb temperature are equal which of the following statements is/are correct?   

1. Air is fully saturated

2. Dew point temperature is reached

3. Partial pressure of vapour equal to the total pressure.

4. Wet bulb temperature and dry bulb temperature

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q28:

Air at state 1 (dpt 10°C, W = 0.0040 kg/kgair) mixes with air at state 2 (dpt 18°C, W = 0.0051 kg/kgair) in the ratio 1 to 3 by weight. The degree of saturation (%) of the mixture is (the specific humidity of saturated air at13.6°C, W = 0.01 kg/kgair)

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q29:

If the volume of moist air with 500 /0 relative humidity is isothermally reduced to half its original volume then relative humidity of moist air become

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q30:

When the lower temperature is fixed. COP of a refrigerating machine can be improve by:

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q31:

The values of enthalpy at the beginning of compression, at the end of compression and at the end of condition are 185 kJ/kg, 210kJ/kg and 85 kJ/kg respectively. What is the value of the COP of the vapour compression refrigeration system?

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q32:

Assertion (A): In vapour compression refrigeration system throttle valve is used and not expansion cylinder.

Reason (A): Throttling is a constant enthalpy process. 

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q33:

The operating temperature of a cold storage is – 20 C. Heat leakage from the surrounding is 30 kW for the ambient temperature of 400 C .The actual COP of the refrigeration plant used is one fourth that of an ideal plant working between the same temperatures. The power required to drive the plant is:

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q34:

A capillary tube is employed in a refrigeration cycle to

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q35:

In a certain ideal refrigeration cycle. The COP of heat pump is 5. The cycle under identical condition as heat engine will have efficiency as

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q36:

The COP of a Carnet heat pump used for heating a room at 200 C by exchanging heat with river water at 100C is:

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q37:

In a reversible cycle the source temperature is 2270 C and the sink temperature is 270 C .the maximum available work for a heat input  of 100 kJ will  be:

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q38:

A Carnot refrigerator works between the temperatures of 200 K and 300 K. if the refrigerator receives 1kW of heat the work requirement will be

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q39:

A refrigerating machine working on reversed carnot cycle takes out 2kW of heat from system at 200 K while working between temperature limits of 300 K and 200 then COP and power consumed by the cycle will be…….

Tags:
Section:
Refrigeration & Air Conditioning
Options:
Q40:

A refrigerating machine working on reversed cycle consumes 6kW to produce a refrigerating effect of 1000kJ min for maintaining a region are - 400C the higher temperature (in degree centigrade) of the cycle will be :

Tags:
Section:
Refrigeration & Air Conditioning
Options: